To View a Control's Description, MouseOver it and ... Click to "Show" - MouseDown to "Drag" - DoubleClick to "Hide"
Flight Deck Photos and/or Graphic Representation
Engine 1 or 2 Fire Switch ( guarded )
When released out, an electrical signal:
Cancels aural warning
Arms squibs
Deactivates generator
Closes the following valves
Fuel LP
Engine fuel return
Hydraulic bleed
Pack flow control
ENG 1 or 2 Fire Lights - Illuminates independently of the switch position as long as the respective Engine Fire warning is activated.
Engine Agent 1 or 2 Switch
Arms when the corresponding ENG FIRE switch is released out. SQUIB lights illuminate to facilitate identification of the agent switch to be activated.
When the AGENT switch is pushed momentarily:
Bottle is discharged
Related DISCH light illuminates
ENG 1 or 2 TEST Switch
Test the fire detection and extinguishing system operation.
Activates ECAM ENG FIRE warning
Activates continuous chime
Illuminates the following:
Flashing MASTER WARN lights
ENG FIRE switch
SQUIB lights
DISCH lights
FIRE lights on engine start and ignition panel
APU Fire Switch ( guarded )
When released out:
Cancels aural warning
APU shuts down
Squib is armed
Squib light illuminates
Fuel LP valve is closed
APU bleed and crossbleed valves are closed
APU generator is deactivated
APU Fire Light - Illuminates independently of switch position when the APU fire warning is activated.
APU Agent Switch
Armed by pushing the APU FIRE switch. SQUIB light illuminates. When the AGENT switch is pushing momentarily:
Bottle is discharged
DISCH light illuminates
APU TEST Switch
Tests fire detection and extinguishing system operation. Does not cause automatic shutdown of APU.