To View a Control's Description, MouseOver it and ... Click to "Show" - MouseDown to "Drag" - DoubleClick to "Hide"
Flight Deck Photos and/or Graphic Representation
ENG 1 & 2 Pump Switch & Light
Switch
ON - The Pump Pressurizes the system when the Engine is running.
OFF - The Pump is depressurized. Power generation stops.
Light - Illuminates amber to indicate:
Reservoir low level
Reservoir overheat
Reservoir low air pressure
Pump low pressure
Extinguishes when the ENG PUMP switch is selected OFF, except during an overheat; in which case,
the light remains on as long as the overheat is present.
ENG 1 & 2 L/R TK Pumps Switch & Fault Lights
Switch
ON - Energize associated Tank Pump; fuel feeds only when center Tank Pumps' delivery pressure drops below threshold.
OFF - Deactivate associated Tank Pump.
Fault Lights - Illuminates amber when the delivery pressure drops. Inhibited when OFF selected.
RAT MAN ON Switch ( Red Guard )
When pushed, the RAM Air Turbine extends. The RAT extends automatically in flight with a loss of AC buses 1 and 2.
Blue ELEC Pump Switch & Fault Light ( Guarded )
Switch
AUTO - The Pump is energized, provided AC power is available:
In flight
On the ground, provided one engine is running or the BLUE PUMP OVRD switch has been pressed.
OFF - The Pump is de-energized.
Fault Light - Illuminates amber to indicate:
Reservoir low level
Reservoir overheat
Reservoir low air pressure
Pump low pressure
Extinguishes when the BLUE ELEC PUMP switch is selected OFF, except during an
overheat; in which case, the light remains on as long as the overheat is present.
PTU Switch & Fault Light
Switch
AUTO - The reversible motor pump is armed and both yellow and
green electro-hydraulic valves are open. The PTU runs automatically
when the differential pressure between the green and yellow
systems is more than 500 psi.
OFF - Both green and yellow PTU electro-hydraulic valves are
energized and close. Power transfer stops.
Fault Light - Illuminates amber to indicate:
Green or yellow reservoir overheat
Green or yellow reservoir low air pressure
Green or yellow reservoir low level
Extinguishes when the PTU switch is selected OFF, except during an overheat; in
which case, the light remains on as long as the overheat is present.
Yellow ELEC Pump & Fault Light
Switch
ON - The Pump is energized. If electrical power is removed the pump remains de-energized at the next electrical power application.
OFF - The Pump is de-energized. It is automatically energized
when the forward or aft cargo door lever is operated. During cargo door operation, all other yellow system users are
inhibited, except for the No. 2 engine thrust reverser and the brake accumulator.
Fault Light - Illuminates amber to indicate:
Reservoir low level
Reservoir overheat
Reservoir low air pressure
Pump low pressure
Extinguishes when the YELLOW ELEC PUMP switch is selected OFF, except during an
overheat; in which case, the light remains on as long as the overheat is present.
X FEED Switch & Open Light
Switch
OFF - Closes Crossfeed valve.
ON - Open Crossfeed valve. ON illuminates white.
Open Light - Illuminates green when Crossfeed valve is fully open.
CTR TK 1 & 2 Pump Switches & Fault Lights
Switch
ON - Activates associated Center Tank Pump. If MAN mode is selected on MODE SEL switch.
OFF - Deactivate associated Center Tank Pump.
Fault Lights - Illuminates amber when the associated Pump is operating and delivery pressure drops.
Mode SEL Switch & Fault Lights
Switch
AUTO - Center Tank Pumps control is automatic:
Pumps operate at engine start for two minutes
Pumps operate provided slats are retracted
Pumps automatically turn off five minutes after Center Tank low level is reached
MAN - Allows manual control of Center Tank Pumps with CTR TK PUMP switches.
Fault Lights - Illuminates amber when Center Tank has more than 550 pounds
of fuel and the left or right wing Tank has less than 11,000 pounds.