ECAM Control
Selects respective display on/off and control brightness. When the upper ECAM display is selected OFF,
the E/WD automatically transfers to the lower ECAM display.
T.O. CONFIG Key
When pushed, simulates takeoff power application to trigger a warning if the airplane is not properly configured for takeoff.
If the airplane is properly configured, the "T.O.CONFIG NORMAL" message in the takeoff memo displays green.
EMER CANC Key (Red)
When pushed:
- Warnings: Present aural warning is cancelled. MASTER WARN lights extinguish. ECAM message display is not affected.
- Cautions: Present Cautions is cancelled for remainder of flight. STATUS page is automatically displayed. "CANCELLED CAUTION"
message and the title of the inhibition is suppressed after AC power application until first engine start, but can be manually recalled by
pushing RCL key for more than 3 seconds.
System Page Keys ( 11 Keys )
When pushed, the related system page appears on the lower ECAM display. Illuminates after manual selection or when an advisory is detected.
If pushed a second time while illuminated, the system page for the present phase of flight or current warning appears.
RCL Key
When pushed, Recalls warning and caution massages that have been suppressed with the CLR key or automatic flight phase inhibition. "NORMAL"
appears for five seconds with no current warnings or cautions. When pushed for more then three seconds, caution messages suppressed by the EMER CANC
key are Recalled.
ALL Key
When pushed and held, all system pages are displayed in succession at one-second intervals. If the ECAM control panel fails, push and hold the ALL Key
until the desired system page appears and then release the key to maintain the display.
If only one ECAM screen is available, repeatedly pressing the ALL Key will cycle to the desired page.
STS Key
Illuminates when ECAM STATUS page is displayed. When pushed, the STATUS page is displayed on the ECAM lower display. When pushed with no present
status messages, "NORMAL" appears for five seconds. The STATUS page may be cleared by pushing the STS key a second time or by pushing
the CLR key.
Left / Right CLR Keys
Illuminates when an ECAM warning, caution, or status message is displayed. When an Illuminated CLR key is pushed, the ECAM display will change.