Side Stick Priority Lights
Arrow Light - Illuminates RED in front of pilot losing authority.
Extinguishes when sidestick activation is reestablished by:
- If the other takeover pushbutton is released prior priority condition is latched, or.
- If he has used his takeover pushbutton to cancel a latched priority situation.
CAPT or F/O Light - Illuminates GREEN to indicate associated Sidestick has established priority by activation
of its priority switch and the opposite Sidestick is not in neutral.
Extinguishes when the opposite is returned to neutral.
Master WARN Light
Flash RED for level 3 Warnings. Accompanied by an aural Warning.
The lights extinguish when:
- Either MASTER WARN light is pushed.
- The Warn no longer exists.
- The CLR key on the ECAM Control Panel is pushed.
- The EMER CANC key on the ECAM Control Panel is pushed.
The aural Warning stops when:
- Either MASTER WARN light is pushed.
- The Warning no longer exists.
- The EMER CANC key on the ECAM Control Panel is pushed.