A340 Hydraulic and Fuel
by jerome meriweather
Maintenance
OverHead
Glareshield
Forward
Pedestal
Up to
ENG Fire
Left to
APU FIRE
Right to
Audio
or
Radio
Down to
ELECT
To View a Control's Description, MouseOver it and ...
Click
to "Show" -
MouseDown
to "Drag" -
DoubleClick
to "Hide"
Flight Deck Photos and/or Graphic Facsimile
RAT MAN ON ( Guarded )
The RAT may be extended at any time by depressing the RAT MAN ON pb.
ELEC Pump Blue ( springloaded-guarded )
OFF:
Pump is de-energized.
ON:
Pump is energized.
FAULT Light:
Illuminates associated with ECAM caution.
CTR Tank L or R
ON:
Associated Center Tank pump runs permanently and the transfer is controlled by the appropriate valves.
OFF:
The Center Tank pump is stopped.
Fault Light:
Illuminates Amber, associated with ECAM caution.
T. Tank Mode
AUTO:
CG is controlled by the FCMC.
FWD:
Manual Forward transfer to the Center Tank is initiated.
Fault Light:
Illuminates Amber with ECAM activation.
T. Tank Feed SEL
AUTO:
Forward transfer is stopped when the trim Tank is at low level to maintain the Transfer line full.
ISOL:
Transfer line is Isolated.
OPEN:
The valves being used for manual forward Transfer and in addition the TRIM TANK INLET valve open.
OUTR TK XFR ( Guarded )
AUTO:
Transfer from Outer to inner tanks is controlled by the FCMC.
ON:
Transfer from Outer to inner tanks is initiated.
FAULT Light:
Illuminates Amber associated with ECAM caution.
Inner Tank 1, 2, 3, 4
ON:
Associated pump is operating.
OFF:
Associated pump is stopped.
Fault Light:
Illuminates Amber associated with ECAM caution, when the delivery pressure drops when the valve is fully open.
Inner Tank STBY 1, 2, 3, 4
ON:
Related Stand-by pump is automatically operated when associated main pump is failed or selected OFF.
OFF:
Associated pump is stopped.
FAULT Light:
Illuminates Amber, associated with ECAM caution when the delivery pressure drops.
X Feed 1, 2, 3, 4
ON:
Both valves automatically open.
OFF:
The valve closes.
Fault Light:
Illuminates Green when the valve is fully open.
ENG 1, 2, 3, 4 Pumps
ON:
Pump pressurizes the system when the Engine is running.
OFF:
Pump is depressurized.
FAULT Light:
Illuminates Amber associated with ECAM caution.
ELEC Pump Green
AUTO:
Green Electric Pump automatically run.
OFF:
Pump is de-energized.
FAULT Light:
Illuminates Amber associated with ECAM caution.
ELEC Pump ON Green ( springloaded-guarded )
AUTO:
Pump is controlled according to the ELEC PUMP pb sw.
ON: